Free4Dump Fire-Inspector-II exam dumps are audited by our certified subject matter experts and published authors for development. Fire-Inspector-II exam dumps are one of the highest quality Fire-Inspector-II Q&AS in the world. It covers nearly 96% real questions and answers, including the entire testing scope. Free4Dump guarantees you Pass Fire-Inspector-II Exam at first attempt.
Free4Dump provides 67 - Fire Inspector II Exam (Fire-Inspector-II) practice tests (desktop and web-based) to its valuable customers so they get the awareness of the Fire-Inspector-II certification exam format. Likewise, 67 - Fire Inspector II Exam (Fire-Inspector-II) exam preparation materials for Fire-Inspector-II exam can be downloaded instantly after you make your purchase.
>> New Fire-Inspector-II Test Notes <<
There are three different versions of our Fire-Inspector-II study guide which are PDF, Software and APP online versions. For their varied advantages, our Fire-Inspector-II learning questions have covered almost all the interests and habits of varied customers groups. No matter you are a student, a working staff, or even a house wife, you will find the exact version of your Fire-Inspector-II Exam Materials to offer you a pleasant study experience.
NEW QUESTION # 14
What fire-resistance rating is required for interior nonbearing walls and partitions in Type IV construction?
Answer: B
Explanation:
Fire-Resistance Rating for Nonbearing Walls in Type IV Construction
Type IV (Heavy Timber) construction, as defined by the International Building Code (IBC) 2021, Section
602.4, consists of large, solid or laminated wood members.
Interior nonbearing walls and partitions in Type IV construction are not required to have a fire-resistance rating (0 hours) unless they separate different occupancies or are specifically mandated by another code provision.
2. Why Type IV Does Not Require a Rating for Nonbearing Walls
The heavy timber components inherently provide fire resistance due to their large cross-section, which chars on the surface and slows fire penetration.
IBC Table 601 confirms that interior nonbearing walls in Type IV construction do not have a required fire- resistance rating.
3. Verification of Other Options
Option B (1 hour) - Incorrect, as Type IV does not require a 1-hour rating for interior nonbearing walls unless specific conditions apply.
Option C (1-1/2 hours) - Incorrect, as there is no code requirement for this level of rating in Type IV nonbearing walls.
Option D (2 hours) - Incorrect, as Type IV walls are not rated unless separating occupancies.
Reference Sources:
International Building Code (IBC) 2021 - Section 602.4 (Type IV Construction Requirements) IBC Table 601 (Fire-Resistance Ratings for Building Elements) ICC Fire Inspector II Study Guide (2021)
NEW QUESTION # 15
Quantities of flammable liquid storage in a control area of an S Occupancy may be doubled when:
Answer: C
Explanation:
The storage of flammable liquids in control areas within an S Occupancy (Storage Occupancy) is governed by the 2021 International Fire Code (IFC), Section 5003 - Hazardous Materials, and Table 5003.1.1(1).
IFC Section 5003.1.1(1) - Maximum Allowable Quantity (MAQ) Adjustments:
The maximum allowable quantity (MAQ) of flammable liquids in a control area may be doubled if an approved automatic sprinkler system is installed throughout the building.
Why Other Options Are Incorrect?
A: Permission is granted by the chief.
Fire officials can enforce code requirements but do not have the authority to override MAQ limits unless explicitly allowed in the code.
B: The control area exceeds 50,000 sq. ft.
The code does not specify an increase based solely on size; the sprinkler system is the determining factor.
D: The control area is provided with exhaust ventilation in accordance with fire code requirements.
While ventilation is important for hazardous material safety, it does not allow for an increase in the maximum storage quantity.
NEW QUESTION # 16
Foamed plastics or materials containing foamed plastics used for stage scenery must be approved when tested in accordance with
Answer: D
Explanation:
Foamed plastics or materials containing foamed plastics used for stage scenery must meet strict fire performance requirements to prevent rapid flame spread and fire hazards in assembly occupancies.
The correct fire test standard for these materials is UL 1975 - Standard for Fire Tests for Foamed Plastics Used for Decorative Purposes.
Reference to Fire Inspector Documentation:
1. 2021 International Fire Code (IFC) - Section 807.4.2 (Foamed Plastics for Stage Scenery) IFC 807.4.2 states that foamed plastics used in scenery must be tested and approved per UL 1975 to ensure fire safety.
2. UL 1975 - Standard for Fire Tests for Foamed Plastics Used for Decorative Purposes This standard evaluates the flammability and smoke production of foamed plastics used in decorative applications, including stage scenery.
Detailed Explanation of Answer Choices:
Option A (Correct): UL 1975 is the required test standard for foamed plastics used in stage scenery, ensuring compliance with IFC 807.4.2.
Option B (Incorrect): NFPA 11A deals with foam-water fire suppression systems, not foamed plastics for decorative use.
Option C (Incorrect): CPSC 16CFR relates to consumer product safety regulations but does not address fire safety for foamed plastics on stage scenery.
Option D (Incorrect): ASTM D 1784 is a test for rigid PVC plastics and does not apply to foamed plastics used for stage scenery.
Thus, the correct and verified answer is: A. UL 1975.
NEW QUESTION # 17
Clearance between tops of piles of combustible fibers and sprinkler heads shall not be less than ___ ft.
Answer: A
Explanation:
Reference to Fire Code Requirements for Clearance Between Combustible Fibers and Sprinklers:
The International Fire Code (IFC 2021), Section 3206.6, states that the minimum clearance between the tops of piles of combustible fibers and sprinkler deflectors shall be no less than 3 feet.
This requirement ensures that the sprinkler system operates efficiently and that water distribution is not obstructed in case of a fire.
Fire Safety Concerns:
Combustible fibers pose a high fire risk due to their flammability and tendency to generate large amounts of heat and smoke.
Adequate clearance prevents heat accumulation near the sprinkler heads, ensuring they activate at the correct temperature.
Clarification of Incorrect Answer Choices:
A: 2 ft. # Incorrect
Too low and could obstruct sprinkler operation, reducing water distribution effectiveness.
C: 4 ft. # Incorrect
Exceeds the required minimum per the IFC 3206.6 standard, though more clearance is beneficial.
D: 5 ft. # Incorrect
More than the code requirement, but the mandatory clearance is 3 feet.
Conclusion:
The correct and verified answer is B (3 feet) based on IFC 3206.6, ensuring proper sprinkler performance and fire safety for combustible fiber storage.
NEW QUESTION # 18
A local board of appeals may perform all of the following functions except:
Answer: A
Explanation:
IFC Section 108 (Board of Appeals) outlines the board's role: it hears appeals on fire code official decisions (Section 108.1), can interpret the code (B), approve alternatives (C) per Section 104.9, and establish procedural rules (D) per Section 108.2. However, the board cannot "waive" code requirements outright (A)- it can only grant variances or approve alternatives that still meet the code's intent, not eliminate requirements entirely. Waiving implies nullification, which exceeds the board's authority; that power rests with the fire code official or legislative amendments. Thus, A is the exception.
NEW QUESTION # 19
......
You just need to get Free4Dump's International Code Council Certification Fire-Inspector-II Exam exercises and answers to do simulation test, you can pass the International Code Council certification Fire-Inspector-II exam successfully. If you have a International Code Council Fire-Inspector-II the authentication certificate, your professional level will be higher than many people, and you can get a good opportunity of promoting job. Add Free4Dump's products to cart right now! Free4Dump can provide you with 24 hours online customer service.
Dumps Fire-Inspector-II Reviews: https://www.free4dump.com/Fire-Inspector-II-braindumps-torrent.html
International Code Council New Fire-Inspector-II Test Notes And as the high pass rate of more than 98%, you will pass for sure with it, So our Fire-Inspector-II Exam Answers study guide can be your best choice, International Code Council New Fire-Inspector-II Test Notes Sooner or later you will be fired by your boss, But it is difficult for most people to pass Dumps Fire-Inspector-II Reviews - 67 - Fire Inspector II Exam exam test, International Code Council Fire-Inspector-II dumps can be downloaded immediately after purchasing.
On the educational front, Arshad holds a Master in Computer Fire-Inspector-II Applications degree and a Master in Business Administration in IT degree, iBooks and PowerBooks have a modem built in.
And as the high pass rate of more than 98%, you will pass for sure with it, So our Fire-Inspector-II Exam Answers study guide can be your best choice, Sooner or later you will be fired by your boss.
But it is difficult for most people to pass 67 - Fire Inspector II Exam exam test, International Code Council Fire-Inspector-II dumps can be downloaded immediately after purchasing.
© Dynamic Technologies. All rights reserved.